EXCELL PRECISION CO., LTD
SI-132 v1.1 SME300000081
22
Press
TARE
key
Key in the parameter 00 ~
08
Key in the parameter 00,
then press
TARE
key to
exit RS232 serial interface
settings
2-5 RS232 SERIAL INTERFACE SETTINGS
In the weighing mode, press the NET/GROSS and ON/ZERO keys at the same time
to enter the Advanced Function setting mode. The LCD shows and
use the NET/GROSS or UNITS key to select to enter the RS232
serial interface setting mode.
4 RS232 serial interface settings span ~ ,
8 settings.
ACTIONS
DISPLAY
NOTE
ON/ZERO
key
Upward key (from 0 to 9)
UNITS
key Downward key (from 9 to 0)
TARE
key Move the cursor to right
NET/GROSS
key Move the cursor to left.
Exit the RS232 serial interface setting mode
Baud rate setting
Communication protocol setting
Output format setting
Continuous transmission setting
The selection of continuous transmission rate
Auto Transmission at Zero
Reset of Auto Transmission
Output condition setting