EXCELL PRECISION CO., LTD.
Ocean User Manual SME300000132
9
ON/ZERO
enter a parameter
4-2 Hold Function Setting
v Restart the scale to activate the setting just done.
Back to weighing mode
ON/ZERO ⇒ Increment digit (from 0 to 9)
TARE ⇒ Confirm / enter key
NET/GROSS ⇒ Move the cursor to the
= Hold function disabled.
= “Peak hold” mode
The scale shows the maximum weight value detected from the continuously changing weight
values. Press any key to exit the hold function.
= “Stable hold 1” mode
After the scale is stable, the display shows the current weight value. Press any key to exit the
hold function.
= “Stable hold 2” mode
After the scale is stable, the display shows the current weight value. Re-zero the scale to exit
the hold function.
Use the
ON/ZERO
key to input a parameter
Default setting = 0
0 ⇒ Hold function disabled
1 ⇒ “Peak hold” mode
2 ⇒ “Stable hold 1” mode
3 ⇒ “Stable hold 2” mode
LCD displays the last parameter setting
TARE
complete the advance
function setting